Description
Plasma Cut Current Range: 20-40A
Plasma Cut Duty Cycle @ 40°C: 25% @ 40A / 60% @ 26A / 100% @ 20A
Mild Steel Cut Thickness: 12mm (INTERNAL) / 16mm (EXTERNAL)
Mild Steel Severance Thickness: 14mm (INTERNAL) / 18mm (EXTERNAL)
Aluminium Cut Thickness: 6mm (INTERNAL) / 8mm (EXTERNAL)
Aluminium Severance Thickness: 8mm (INTERNAL) / 10mm (EXTERNAL)
Stainless Steel Cut Thickness: 6mm (INTERNAL) / 8mm (EXTERNAL)
Stainless Steel Severance Thickness: 8mm (INTERNAL) / 10mm (EXTERNAL)
Air Flow Draw Off (L/min): 120
Air Flow Pressure (Bar): 5.17 (75 psi)
Plasma Arc Start: Pilot Arc